Teledyne ML9830 Carbon Monoxide Analyzer
The Teledyne ML®
9830 Carbon Monoxide Analyzer is a
non-dispersive infrared (NDIR) photometer which uses gas filter correlation technology to
measure low concentrations of CO accurately and reliably. This instrument utilizes a
broadband infrared radiation source located behind a rotating gas filter correlation
wheel. The correlation wheel has two gas filled "cells," one contains the CO
which removes all IR energy in the CO absorption wavelengths thereby creating a reference
beam. The other cell contains nitrogen which allows the CO absorption spectral bands to be
measured with the sample gas. Both IR beams pass sequentially through the multiple path
measurement cell where the energy is absorbed by the sample gas. The difference in IR
energy sensed by the solid state detector during measurement and reference cycles is
proportional to the CO present in the measurement cell. This ratiometric technique
eliminates most of the sources of drift typical of other less sophisticated analyzers.
Features:
for maximum specificity and sensitivity, uses a long
life (IR) source and advanced materials in the gas filter wheel for minimum maintenance.
Built-in Zero Air Scrubber - Ensures zero stability
with need for an outside scrubbing medium.
Software Based Multi-Point Linearization - Provides
linear response over the full scale range.
Variable Sample Flow Rate - Enables the analyzer to
purge the sample cell quickly during calibration and thus, maximize sample measurement
time.
U.S. EPA Reference Method Designation RFCA-0992-088
Eignungsgepr Üft-Bericht Nr. 3.5.1/554/92 RW TÜV,
Essen, Germany
Teledyne ML®9820 Ambient
Carbon Dioxide Analyzer
The
Teledyne ML® 9820 is a gas filter correlation
non-dispersive infrared based instrument designed to measure ambient concentrations of
carbon dioxide. This instrument utilizes a broadband infrared radiation source located
behind a rotating gas filter correlation wheel. The correlation wheel has two gas filled
"cells," one contains the CO2 which removes all IR energy in the CO2 wavelengths
thereby creating a reference beam. The other cell contains nitrogen which allows the CO2
in the sample to be measured. The IR beam passes through the multiple path measurement
cell where the energy is absorbed by the sample gas. The difference in IR energy sensed by
the solid state detector during measurement and reference cycles is proportional to the
CO2 present in the measurement cell. The ratiometric technique eliminates most of the
sources of drift typical of other less sophisticated analyzers.
Features:
Gas correlation infrared measurement of
Carbon Dioxide
Differential or absolute measurements
from user supplied zero air
Three full scale ranges available to
maximize data linearity
CO2 is not a criteria
pollutant and thus does not require an EPA equivalency designation.
|
|