Ethylene, “The King of Petrochemicals", is the base material for many petrochemical products. Commercial goods we use every day, such as engine coolant, synthetic rubbers and PVC, are manufactured from ethylene. Ethylene is the first member of alkenes, which also includes: propylene, butylene's, and butadiene's. Ethylene is produced from Natural Gas, LPG, Naphtha or refinery oil; however, with the abundance of Shale Gas, Ethane/Propane and natural gas are the most popular feedstock in the production of Ethylene in North America. Regardless of the feedstock, the basic process for ethylene and olefin production is similar. Each ethylene plant has multiple steam furnace crackers to handle a variety of feed types. Once cracked, the effluent is quenched, compressed and prepared for fractionation into petrochemical products.
Teledyne systems provide efficient, effective and reliable support, data storage and reporting for the refining process and source emissions.
-
Real-time optimization of transitional chemical processes for hydrocarbon makeup, purity, impurity measurements and simulated distillation
-
H2S and
Heating Value BTU analysis for flares
-
Makeup, Condensate, Feed, Cooling and Effluent Water Quality Analysis pH, ORP, conductivity, turbidity, oil in water, THC, and dissolved O2; 40 CFR 419/458, 40CFR60 Subpart QQQ, 40CFR63 Subparts Q, CC and Canadian Liquid Effluent Regulations and Waste Water Effluent Guidelines
-
Complete Monitoring Systems for combustion emissions, ambient, and
water sources for worldwide and US EPA NSPS, NESHAP, and Greenhouse Gas rules
Analysis Point |
Stream |
Components Measured |
Teledyne Products |
Furnace (Hot) Side | Feed Analysis (Compositional) | C2, C2=, C3, C3= |
Teledyne Falcon Series GC |
Feed Analysis (Safety) | H2S |
Model 6020L - H2S |
Quick Effluent Efficiency Analysis | C2, C2=, C3, C3= |
Teledyne Falcon Series GC
(Recommended to be paired with suitable Pyrolysis Probe unit) |
Complete Compositional Measurement | H2, C1 to C5 + |
Teledyne Falcon Series GC
(Recommended to be paired with suitable Pyrolysis Probe unit) |
Fractionation Towers | Purity measurements of Methane, Ethylene, Propylene, compositional analysis of Mix Olefins and Gasoline | Various compositions of C1 to C5+, configuration based on the installation point and measurement |
Teledyne Falcon Series GC
-Gas Phase Analysis -Liquid Phase Analysis for Mix Olefins & Gasoline |
Impurity measurements | PPM levels of O2 in Ethylene |
TAI Model 3020T Electrochemical Sensor |
Impurity measurements | PPM levels of CO, CO2 in Hydrogen |
TAI 7600Z multi-gas analyzer |
Utilities (Water) | Boiler Feed Water and Condensate Water | PH, Conductivity, Dissolved Oxygen |
Teledyne Model LXT380 with SP3X - Intelligent Sensors |
Boiler Feed Water and Condensate Water | Total Hydrocarbon |
TAI Model 4080 |
Environmental | Flue Gas/Emission Gas and performance indicators for Boilers, Furnaces, and RTO | CO, CO2, NOx, O2, Opacity, SO2, VOC, Exhaust Gas Flow |
TAI Model 660, TML Full CEMS |
Flue Gas/Emission Gas from Flares | H2, H2S, NHV, O2, Exhaust Gas Flow |
Teledyne Falcon Series GC,
TML UltraFlow 150 |
Introducing our multi-purpose gas chromatograph for use in hot side or downstream production, quality assurance and control:
The Teledyne Falcon Gas Chromatograph is a fast and superior analyzer perfect for process sampling and field testing to verify consistency of materials and processes. Fence line or exhaust Benzene or VOC monitoring can be performed continuously or on an intermittent (portable) basis. The Teledyne Falcon GC paired with an FID detector will speciate hydrocarbons in a fuel sample for determining fuel quality and heating value. The simplified modular design means that a technician can swap a column or detector and perform maintenance quickly and with minimal training.
Teledyne's Ultra-fast Gas Chromatograph is:
▶ FASTER, ▶ SMALLER, ▶ SMARTER, ▶ EASIER, ▶ GREENER
- Fast cycle times with true composition measurements suitable for composition control in near real-time
- Adaptable to many challenging applications such as purity, impurity measurements and simulated distillation
- Scrutinize data rich measurement results in the laboratory
- Portable units available for field testing
- Low power consumption
- Auto sampler and Sample splitter available
- ASTM Methods D2887, D7798, D3710, D7096, D86
-
Chromperfect® Chromatography Data System